BioScan BSC-101 ¢â Àº µ¶¸³ÀûÀ̸鼭µµ , ³×Æ®¿öÅ©¿ëÀ¸·Î ÀÚü ÃæÁ·ÀÌ µÇ´Â Å͹̳ημ­´Â °¡Àå Áøº¸µÈ Áö¹® ÀÎ½Ä ±â¼úÀÔ´Ï´Ù. Á¢±Ù Á¦¾î¸¦ À§ÇÑ »ýü ÆÇµ¶±â, ±ÙÁ¢ ÆÇµ¶±â, ÇÉÆÐµå ±â±â ¸ðµÎ°¡ ÅëÇյǾî ÀÖ´Â ¿ÃÀοø ¼Ö·ç¼ÇÀÔ´Ï´Ù.
 
   
  BioScan BSC-101 ¢â Àº Á¢±Ù Á¦¾î¸¦ À§ÇÑ »ýü ÆÇµ¶±â , ±ÙÁ¢ ÆÇµ¶±â, ÇÉÆÐµå±â±â ¸ðµÎ°¡ ÅëÇյǾî ÀÖ´Â ¿ÃÀοø ¼Ö·ç¼ÇÀÔ´Ï´Ù. BioScanÀº Á¦¾î ½Ã½ºÅÛ¿¡ Á¢±ÙÇÏ´Â Áö¹® ÀÎ½Ä ±â¼úÀÇ Æí¸®ÇÔ°ú º¸¾ÈÀ» ´õÇØÁÖ´Â µ¥ ÇÊ¿äÇÑ ºñ¿ëÀ» ÁÙ¿©ÁÝ´Ï´Ù. ¸ÕÁö°¡ ³¤ »óȲ¿¡¼­µµ Áö¹®À» ÀνÄÇÏ´Â ´É·ÂÀÌ Àֱ⠶§¹®¿¡, BioScanÀº ÀÌÀü¿¡´Â »ýü±â¹Ý Á¢±Ù ¼Ö·ç¼ÇÀ» ¼³Ä¡ÇÏÁö ¸øÇß´ø °øÀå, °Ç¼³ÇöÀå µî¿¡ À¯¿ëÇÕ´Ï´Ù.
 

•  ÃÖ÷´Ü Áö¹® ¾Ë°í¸®Áò (Áö¹® ÀÎ½Ä °æÀï, FVC2004¿¡¼­ 1À§)

•  1ÃÊ ³»·Î 1:1 ÀÎÁõ°ú 1:´Ù ÀνÄ

•  °¢ °³Àθ¶´Ù 2°³¿¡¼­ 4°³±îÁö Áö¹® µî·Ï °¡´É

•  ´Ù¾çÇÑ º¸¾È ¸ðµå : ÃÑ 11°³±îÁö ¿î¿µ ¸ðµå ¼±Åà °¡´É.

•  »ç¿ëÀÚ Ç¥½Ã È­¸é°ú Áغñ È­¸éÀ» »ç¿ëÀÚ ¼³Á¤ÇÒ ¼ö ÀÖÀ½ .

•  ¹é¶óÀÌÆ® 32±ÛÀÚ LCDÈ­¸é°ú 16°³ ¼ýÀÚ Å°ÆÐµå

•  20°³ÀÇ ÇÁ·Î±×·¥ °¡´É ±â´É Ű

•  6°³ÀÇ ÇÁ·Î±×·¥ °¡´É ³»Àå ÀÔ·Â / 2°³ÀÇ ¸±·¹ÀÌ Ãâ·Â

•  Ãß°¡ º¸¾È ±¸¼ºÀ» À§ÇÑ ¿ÜºÎ ¿ø°Ý ¸±·¹ÀÌ ¸ðµâ ¼±Åà °¡´É

•  ¿ÜºÎ °æº¸ ½Ã½ºÅÛ ÀåÂø¿ë º¸Á¶ ¸±·¹ÀÌ

•  ÃâÀÔ ÀåÄ¡º° ÀÔÃâ Á¦Çѱâ´É (Anti-passback)¿ë ¿ÜºÎ ÀÎ½Ä±â Æ÷Æ®

•  RS232/RS422, TCP/IP¸¦ ÅëÇÑ ´Üµ¶ ÀÛµ¿/³×Æ®¿öÅ© Åë½Å

•  Á¢±Ù Á¦¾î¿Í ±ÙÅ °ü¸® ¼ÒÇÁÆ®¿þ¾î µà¾ó ÀÎÅÍÆäÀ̽º

•  Ãß°¡ ±â´É¿ë ¹«·á ¼ÒÇÁÆ®¿þ¾î¿Í SDK

•  512 ½Ã°£´ë Áö¿ø

•  365ÀÏ °øÈÞÀÏ Áö¿ø

»ç¿ëÀÚ µî·Ï
1,900 ÅÛÇø´
Æ®·£Àè¼Ç ¹öÆÛ
16,000 Æ®·£Àè¼Ç
Åë½Å
Ç¥ÁØ
Ç¥ÁØ Wiegand 26-ºñÆ® & RS232
¼±ÅÃ
RS422, RS485 & Ethernet
Ç¥½ÃºÎ
ºÓÀº»ö LED
Access Denied
³ì»ö LED
Access Granted
³×Æ®¿öÅ· ¼ÒÇÁÆ®¿þ¾î
½Ç¹ö
Access Control Software
°ñµå
Time and Attendance Software
ÇÊ¿ä Àü¿ø
12V DC 500mA
¹°¸®Àû Ư¡
Dimention
H130 * W147 * D39mm
Material
ABS (Polycarbonate)
ȯ°æ
Temperature
-0C ~ 50C
Humidity
10% ~ 90%
¼º´É
Reading Range
5 ~ 10cm (Aproximately)
FAR
0.00008%
FRR
0.09%
Verification Time
0.5 ~ 1 Seconds
ÀÔ·Â & Ãâ·Â
Customizable 6 inputs and 2 outputs
Ãßõ ÄÉÀ̺í
* ALPHA 6212C, 2-Twisted Pair, and Shield Cable with
--Drain Wire
* Belden No. 9329-22 AWG for 1000 ft (305m) maximum
--distance
* Belden No. 9369-18 AWG for 4000 ft (1220m) maximum
--distance
¼±ÅûçÇ×
External Reader
ISR-100 / ISR-200 / ISR-300 / BSR-100
Reader Type
EM & HID or Mifare
º¸Áõ
1 year parts and labor
       * Specifications subject to change without notice
Model
Reader Type
Network Type
BSC-101-E10
EM&HID Reader
RS232
BSC-101-E20
EM&HID Reader
RS232, RS422 & RS485
BSC-101-E30
EM&HID Reader
RS232 & Ethernet
BSC-101-M10
Mifare Reader
RS232
BSC-101-M20
Mifare Reader
RS232, RS422 & RS485
BSC-101-M30
Mifare Reader
RS232 & Ethernet
BSC-101-N05
Without Prox Reader
RS232
BSC-101-N15
Without Prox Reader
RS232, RS422 & RS485
BSC-101-N25